Artikeldetails
Siemens Advia Centaur XP Analyzer System Acridinium Ester Immunoassay Technology
Siemens Healthineers Service and Maintenance until 02/2022
Modern AE Immunoassay Technology
Fulfillment of clinical requirements using acridinium ester (AE) technology, which provides the necessary flexibility and sensitivity for new and innovative assays.
Comprehensive diagnostic clarification of various disease patterns thanks to a test menu with over 70 different assays.
Simplified inventory management and lower costs through the use of the same ready-to-use reagents on all ADVIA Centaur analyzer systems.
Simplified operation, continuous operation
All samples, reagents and consumables can be loaded and unloaded during ongoing operation.
Easier training and operation thanks to an intuitive, icon-based user interface.
Fewer operator interventions, as the daily maintenance effort is low and the system does not need to be cleaned monthly or started up daily.
New and updated test definitions can be read in by the customer by simply scanning the 2D barcodes contained in the instructions for use.
Consistent, plannable turnaround time (TAT) and accuracy
Up to 240 tests/hour for a short turnaround time even at peak times.
Rapid prioritization of emergency samples thanks to a dedicated access (STAT port) possible at any time.
Disposable pipette tips prevent carryover and contamination of samples.
Automatic performance of repeat and confirmation tests for reactive hepatitis B surface antigen samples with Siemens Healthineers' SMART algorithms.
Direct connection capability
Adaptation to different sample volumes through easy connection to Aptio and VersaCell® X3 automation solutions.
Efficient operation thanks to diagnostic IT including CentraLink® data management system
Atellica Process Manager and Smart Remote Services for Diagnostics
Direct pipetting from the automation solution through point-in-space technology.
Shorter processing times for emergency samples thanks to a dedicated STAT port, which also allows loading of emergency samples via the front when connected to an automation solution.
Technical Specifications
Product specifications
System type: Random Access Immunoassay System
Throughput: Up to 240 tests per hour
Time to first result
18 minutes, further results in 15-second intervals (method-dependent)
On-board method capacity: 30 test methods
Indication groups§§
Allergy, Anemia, Diabetes, Fertility, Hepatitis, HIV, Immunosuppressants, Infection serology, Cardiology,
Bone metabolism, Liver fibrosis, Adrenal function, Oncology, Thyroid disorders, Sepsis, Therapeutic Drug Monitoring (TDM)
Continuous operation
Loading and unloading of samples and consumables at any time during ongoing operation. This includes sample racks, emergency samples, reagents, additional reagents, reaction cuvettes, sample tips, calibrators, controls, wash solutions, water and waste.
Samples and sample management: Sample tubes
3 ml, 5 ml, 7 ml and 10 ml tubes, 1 ml and 2 ml secondary tubes, micro tubes
Sample supply
Universal rack with 5 positions for different tube types, total capacity 180 samples; Loading and unloading during ongoing operation
Validated sample types
Serum, plasma, urine, whole blood (depending on the test method)
Sample volume per test
10–200 μl, depending on the test method
Sample integrity check
Pressure sensor technology with clot detection and management, monitoring of sample volume including low volume detection and management; each with marking and documentation
Emergency sample management
Emergency samples can be added at any time via a dedicated access (STAT port); Emergency samples are analyzed with priority
Automatic test repetition: User-definable
Sample dilution
Automatic further dilution (up to 1:2500), depending on the test method
Automatic reflex testing
Automatic performance of additional tests, depending on the results of the first test
Pipette tips
Capacity sufficient for 840 disposable sample tips
Protection against carryover between samples
Disposable pipette tips prevent carryover between samples
Barcodes
Sample barcodes
Up to 20 characters, Interleaved 2 of 5, Code 39, Code 128, Codabar, A, B and special characters (.-+/*$%)
Reaction range
Reaction cuvettes
Capacity sufficient for 1,000 high-quality plastic cuvettes
Reaction environment: Air-conditioned, 37 °C
Calculation of the test result
Test repetition and confirmation of the test reaction using the SMART algorithm software, output of the result after completion
Assay technology
Chemiluminescence with modern acridinium ester technology
Reagent management
Reagent management
Reagent compartment with 30 positions, cooled (between 4°C and 10°C), automatic mixing of ReadyPacks
Onboard reagent capacity: 30 tests
Reagent containers
ADVIA Centaur® ReadyPack® (various pack sizes available)
Reagent integrity check
Reagent identification via barcode, automatic inventory, recording of calibration validity, recording of reagent stability in the system, each including marking and documentation, notification of expired/low reagent stocks
Onboard stability
28 days (on average)
Mixing of reagents
ADVIA Centaur ReadyPacks are automatically kept in motion in the system
Additional reagents
Additional reagent compartment with 25 positions, cooled (4–8°C)
Calibration/Quality control (QC)
Auto-calibration/Auto-QC
Automatic QC, optionally by test count, control, date and time
QC data
Powerful QC package with Levey-Jennings charts, Westgard rules and RiliBÄK support
User interface/Data management
Monitor
22-inch LCD touchscreen monitor with height adjustment
Operating system: Microsoft Windows 7
System documentation
User manual, quick start guide and context-sensitive online help
Data storage
1,000,000 test results/QC results, backup to removable data carriers possible
Onboard maintenance logs and host interface
Bidirectional RS232C with host query, Ethernet connection available
Host query: And
Remote access and maintenance
1000BASE-T Ethernet port for remote access and modem for remote maintenance by Siemens Healthineers with Smart Remote Services
Removable data carriers: CD, DVD or USB stick
General technical data
Power supply
200–240 V at 50/60 Hz; max. 1.2 kW
Maximum water consumption: 2.5 liters per hour
Wastewater requirements
At least 2.5 liters per hour
Dimensions
With monitor: 167 x 196 x 104 cm (H x W x D)
Without monitor: 133 x 196 x 104 cm (H x W x D)
Weight: 585 kg
000
Compliance
Meets international environmental, health and safety standards
Noise level: max. 65dB
Heat dissipation during operation: 5,100 BTU/hour
Ambient temperature: 18–30°C
Humidity
20–80%, non-condensing; both ambient temperature and humidity are monitored by the system
Floor load capacity: 412kg/m²
Manufacturer link
https://www.siemens-healthineers.com/en/immunoassay/systems/advia-centaur-xpt
You can find additional Advia accessories such as Wash Solutions, Cuvette Conditioner, Mixer Rods, Buffer or Probes in our shop.
Find more new and used items in our shop! International shipping costs on request!
Technische Daten
Technical Specifications
Product Specifications
System Type: Random-Access Immunoassay System
Throughput: Up to 240 tests per hour
Time to first result
18 minutes, further results in 15-second intervals (method-dependent)
On-board Assay Capacity: 30 test methods
Indication Groups§§
Allergy, Anemia, Diabetes, Fertility, Hepatitis, HIV, Immunosuppressants, Infectious Serology, Cardiology,
Bone Metabolism, Liver Fibrosis, Adrenal Function, Oncology, Thyroid Disorders, Sepsis, Therapeutic Drug Monitoring (TDM)
Continuous Operation
Loading and unloading of samples and consumables at any time during operation. This includes sample racks, STAT samples, reagents, additional reagents, reaction cuvettes, sample tips, calibrators, controls, wash solutions, water, and waste.
Samples and Sample Management: Sample Tubes
3 ml, 5 ml, 7 ml and 10 ml tubes, 1 ml and 2 ml secondary tubes, micro tubes
Sample Handling
Universal rack with 5 positions for different tube types, total capacity 180 samples; Loading and unloading during operation
Validated Sample Types
Serum, plasma, urine, whole blood (depending on the test method)
Sample Volume per Test
10–200 μl, depending on the test method
Sample Integrity Check
Pressure sensor technology with clot detection and management, sample volume monitoring including low volume detection and management; each with marking and documentation
STAT Sample Management
STAT samples can be added at any time via a dedicated access (STAT port); STAT samples are analyzed with priority
Automatic Rerun: User-definable
Sample Dilution
Automatic further dilution (up to 1:2500), depending on the test method
Automatic Reflex Testing
Automatic performance of additional tests, depending on the results of the first test
Pipette Tips
Capacity sufficient for 840 disposable sample tips
Protection against Carryover between Samples
Disposable pipette tips prevent carryover between samples
Barcodes
Sample Barcodes
Up to 20 characters, Interleaved 2 of 5, Code 39, Code 128, Codabar, A, B and special characters (.-+/*$%)
Reaction Range
Reaction Cuvettes
Capacity sufficient for 1,000 high-quality plastic cuvettes
Reaction environment: Air-conditioned, 37 °C
Calculation of the test result
Test repetition and confirmation of the test reaction using the SMART algorithm software, result output after completion
Assay technology
Chemiluminescence with modern acridinium ester technology
Reagent management
Reagent management
Reagent compartment with 30 positions, cooled (between 4°C and 10°C), automatic mixing of ReadyPacks
Onboard reagent capacity: 30 tests
Reagent containers
ADVIA Centaur® ReadyPack® (various pack sizes available)
Reagent integrity check
Reagent identification via barcode, automatic inventory, recording of calibration validity, recording of reagent stability in the system, each including marking and documentation, notification of expired/low reagent stocks
Onboard stability
28 days (on average)
Mixing of reagents
ADVIA Centaur ReadyPacks are automatically kept in motion in the system
Additional reagents
Additional reagent compartment with 25 positions, cooled (4–8°C)
Calibration/Quality control (QC)
Auto-calibration/Auto-QC
Automatic QC, optionally by test count, control, date and time
QC data
Powerful QC package with Levey-Jennings charts, Westgard rules and RiliBÄK support
User interface/Data management
Monitor
22-inch LCD touchscreen monitor with height adjustment
Operating system: Microsoft Windows 7
System documentation
User manual, quick start guide and context-sensitive online help
Data storage
1,000,000 test results/QC results, backup to removable data carriers possible
Onboard maintenance logs and host interface
Bidirectional RS232C with host query, Ethernet connection available
Host query: And
Remote access and maintenance
1000BASE-T Ethernet port for remote access and modem for remote maintenance by Siemens Healthineers with Smart Remote Services
Removable data carriers: CD, DVD or USB stick
General technical data
Power supply
200–240 V at 50/60 Hz; max. 1.2 kW
Maximum water consumption: 2.5 liters per hour
Wastewater requirements
At least 2.5 liters per hour
Dimensions
With monitor: 167 x 196 x 104 cm (H x W x D)
Without monitor: 133 x 196 x 104 cm (H x W x D)
Weight: 585 kg
000
Compliance
Meets international environmental, health and safety standards
Noise level: max. 65dB
Heat dissipation during operation: 5,100 BTU/hour
Ambient temperature: 18–30°C
Humidity
20–80%, non-condensing; both ambient temperature and humidity are monitored by the system
Floor load capacity: 412kg/m²
Manufacturer link
https://www.siemens-healthineers.com/en/immunoassay/systems/advia-centaur-xpt
Rechtliche Hinweise – Klicken Sie hier für weitere Informationen